Water that stays after rain
Puddles still sitting on the roof long after the rain stops.

Flat and low-slope roofs usually leak at seams, flashing, drains and penetrations. Citium finds the failing detail on TPO, modified bitumen and older roofs and repairs it, or tells you when the membrane is past repair.
Flat roofs in Southern California show up over porches, carports, garages, room additions and mid-century homes. Most aren't truly flat. They're low-slope roofs designed to move water slowly toward a drain, scupper or edge, and they use a continuous membrane instead of overlapping shingles or tile.
Because water moves slowly, small openings matter more. A seam that would be fine on a steep roof can leak on a flat one, and water that gets under a membrane can travel before it shows up inside.
Puddles still sitting on the roof long after the rain stops.
Raised spots in the membrane where moisture or air is trapped.
Surface cracking, splits at seams, or membrane pulling away from walls.
Bare, dark patches on a modified bitumen roof where the protective granules wore off.
Leaves and dust packed at drain openings, often visible from a second-story window.
Ceiling spots under the flat section, especially near walls where it meets the house.
Low spots, blocked drains or a roof built without enough slope leave standing water, which speeds wear and finds weak seams.
Seams are where membrane sheets join. Heat-welded TPO seams and lapped modified bitumen seams both open up with age, movement and poor original work.
Pipes, vents, conduit and equipment supports through the roof need flashing. Old pitch pans filled with tar crack and let water in.
Service techs walking the roof puncture and scuff membranes, and units sitting too low sit in water.
Where a flat roof meets a wall of the house, the membrane has to turn up the wall and terminate properly. This transition is a common leak point on mixed pitched-and-flat homes.
Roofs with layer over layer can hold water inside, so leaks show up far from the entry point.
| TPO | Modified bitumen (torch-down) | |
|---|---|---|
| What it is | 60-mil single-ply membrane with heat-welded seams | Layered assembly, such as base, ply and mineral cap sheet |
| Typical repair | Clean the membrane and heat-weld a patch or re-weld the seam | Patch with a compatible cap sheet over the prepared area |
| What limits repair | Age, dirt and contamination affect whether new material welds well | Brittle, cracked cap sheets and trapped moisture |
| Special considerations | Weld quality depends on surface prep | Torch work requires fire precautions and isn't right for every spot |
| Factor | Repair usually makes sense | Replacement is usually the honest answer |
|---|---|---|
| Extent | One seam, one penetration, or a small area | Leaks in several places or across the field |
| Membrane condition | Flexible and intact around the problem | Brittle, cracked, shrinking or bare of granules |
| Insulation and deck | Dry | Wet or soft across large areas |
| Drainage | Clearing a drain fixes the ponding | The roof needs re-sloping or new drains |
We inspect seams, flashing, penetrations and drains around and uphill of the leak, since water can travel under the membrane.
Drains and scuppers are cleared and checked, and low spots are noted.
Soft or spongy spots indicate wet insulation or decking that has to be addressed with the repair.
The scope names the repair method and materials for your membrane type.
Clean and prepare the membrane, then patch, re-weld or rebuild the flashing or seam with compatible materials.
We check the repair and drainage with you. Tell us if anything reappears in the next rain.
A flat roof inspection looks at the whole membrane, every seam and penetration, the wall and parapet transitions, the edges, and each drain or scupper. We note ponding areas, blisters and soft spots, and on mixed homes we look at where the flat roof meets the pitched roof, because both systems have to shed water across that joint.
Matched to the existing membrane for patches and seam repairs, heat-welded in place.
Compatible base and cap sheets for patches on torch-down and other modified bitumen roofs.
New flashing at walls and penetrations, and termination details that actually hold the membrane edge.
Coatings are a maintenance tool for a sound membrane. They don't fix open seams or failed flashing.
UV and heat age exposed membranes and dry out cap sheets, especially dark ones.
Santa Ana winds and the dry season fill drains and scuppers before the first storm.
Clear drains and fix seams in fall, before water sits on the roof for days.
If more than a repair is needed, Title 24 can require a cool-rated membrane when most or all of a roof is replaced.
Sources: California Energy Commission, 2025 Building Energy Efficiency Standards (Title 24, Part 6); California Energy Commission, Cool Roofs fact sheet (reroof trigger when more than 50% of a roof is replaced; climate zone, slope and exceptions apply)
Many flat roof problems can be repaired when the damage is limited to a seam, penetration or small area and the membrane is still flexible. Age, contamination, wet insulation and the extent of damage decide whether a repair will last.
Heavy or long storms raise water levels on a flat roof, especially if a drain is partly blocked, and that water reaches seams and flashing that normally stay dry. Wind-driven rain can also push water into wall transitions.
Water that sits on the roof long after rain speeds membrane wear, adds weight and finds any weak seam. Clearing drains fixes some ponding; low spots may need tapered insulation or a new drain.
Yes. TPO seams and punctures are repaired by cleaning the membrane and heat-welding a patch or re-welding the seam. Older or contaminated membranes may not weld well, which the inspection checks.
Torch-applied roofing needs fire precautions and a qualified assessment of the site. It's one of several methods, and some areas are better repaired with a different application.
It depends on the membrane type, the size of the damaged area, whether insulation or decking is wet, drainage work, and access. Citium inspects first and puts the price in writing.
Coatings can extend the life of a sound membrane, but they don't fix open seams, failed flashing or wet insulation. Repair the defects first.
Call 818-531-1277, email citiuminc@gmail.com, or request an estimate online. Citium Roofing Solutions is at 401 N Brand Blvd, Unit L106B, Glendale, CA 91203.